1322 Uppsatser om Prevent Moisture damage. - Sida 1 av 89

Fuktskador i bostadskök : En undersökning om fuktskador i kök och hur dessa kan förebyggas vid nyproduktion

Moisture damage in kitchens is an area that many people believe to be irrelevant andnot a subject to concern, however the problems encountered might be larger thananticipated.The purpose of this essay is to get a view of how problematic moisture damagecurrently is as well as what can be done to prevent damage during the constructionand building of new housing.Statistics regarding moisture damage as well as several tools for damage preventionhave been studied and investigated. Industrial regulations have been reviewed tounderstand the requirements construction companies must legally follow during theconstruction and building of new kitchens. Home manufacturers and largerentrepreneurs have been contacted in order to get their point of view regarding theproblems with moisture damages in kitchens.The knowledge of moisture safe constructions is prevalent by home manufacturers,insurance companies and entrepreneurs. Despite this knowledge, the constructioncompanies predominately follow the industries regulations, which normally onlyimplement the minimum requirements.In order to get construction companies to design and build kitchens with increasedmoisture security, stricter industrial regulations might be needed to be implemented.Unlike bathrooms and laundry rooms, kitchens are not defined as a ?wet room? andthe regulations for the construction of kitchens are more lenient.It is difficult to detect water leaks in an early state and the moisture damage is usuallyextensive before it is discovered and repaired if the kitchen lacks moisture securedconstruction and water security.

Fuktskador i ytterväggar på grund av vattenintrång

Moisture damage in buildings is a serious issue that leads to problematic consequences and high economic costs. Despite the knowledge and awareness existing about moisture problems, extensive damager still occurs today. Studies of moisture in the exterior wall constructions shows that the issue if often caused by rain and water intrusion. These kinds of problem result in major costs usually because the companies have to replace the material and structural components and also in some cases tear down large parts of the buildings.The work includes moisture theory and descriptions of four different exterior wall constructions, wood stud wall with plastered facade, exterior wall with wood facade, exterior wall with concrete, and exterior wall with brick facade. Our thesis work describes how the constructions are affected and moisture damage due to water intrusion.

Fukt i byggnadsmaterial : Hur man förebygger fuktskador vid materialhantering på byggarbetsplatsen

Byggsektorn har fortfarande svårigheter med att hantera fuktproblematiken.  Vi har valt att fokusera på hanteringen av material i produktion. Den informationssamling vi utfört ligger till grund för vår analys och slutsats. Vi har intervjuat flera olika entreprenörer från byggbranschen för att ge oss en helhetssyn av fuktsäkerheten ute på byggarbetsplatserna. Studien påvisar att det råder brister både på beställar- och entreprenörssidan. Vi ser att det finns potential för förbättring när det så krävs.

Förbättring av U-värde i träkonstruktion för fönster med Aerogel

When constructing a building, a number of aspects must be harmonized in order for it to fulfill requirements ? a building must fulfill requirements such a load-bearing, conservation of energy and a good indoor environment by means of, among other things, moisture proofing .Moisture problems in buildings can affect health negatively. As we are increasingly staying in indoors, demands on a good indoor environment are higher.This work starts with examining moisture problems in slab-on-ground solutions, and then links the various scenarios to moisture problems in a concrete slab of a real building. The building with moisture problems is located in Årby by in Borlänge and moisture damage was found in the slab at an apartment adjoining wall.By reviewing literature written within the field of moisture problem, making hand calculations and modeling in the program Comsol Multiphysics, judgments are made to find explanations as to why the rise of moisture occurred in the building in Årby by.Generally, the following guidelines may be used to reduce the risk of moisture problems in slab-on-ground constructions:Drying of construction moisture before laying the floor material.Using draining layer beneath the slab, to prevent capillary suction.Using insulation under the slab, partly for comfort and to establish the temperature difference between the ground and the concrete slab.Avoid direct contact between the wood and concrete, due to degradation and fouling smells that normally occurs.If necessary, use additional vapor barrier.In addition to the above, there are various methods for moisture-proof and moisture-monitoring by design or by the method ByggaF suited for the entire construction process various events..

Fuktproblematik i platta på mark : En analys av uppkomsten till fuktproblem

When constructing a building, a number of aspects must be harmonized in order for it to fulfill requirements ? a building must fulfill requirements such a load-bearing, conservation of energy and a good indoor environment by means of, among other things, moisture proofing .Moisture problems in buildings can affect health negatively. As we are increasingly staying in indoors, demands on a good indoor environment are higher.This work starts with examining moisture problems in slab-on-ground solutions, and then links the various scenarios to moisture problems in a concrete slab of a real building. The building with moisture problems is located in Årby by in Borlänge and moisture damage was found in the slab at an apartment adjoining wall.By reviewing literature written within the field of moisture problem, making hand calculations and modeling in the program Comsol Multiphysics, judgments are made to find explanations as to why the rise of moisture occurred in the building in Årby by.Generally, the following guidelines may be used to reduce the risk of moisture problems in slab-on-ground constructions:Drying of construction moisture before laying the floor material.Using draining layer beneath the slab, to prevent capillary suction.Using insulation under the slab, partly for comfort and to establish the temperature difference between the ground and the concrete slab.Avoid direct contact between the wood and concrete, due to degradation and fouling smells that normally occurs.If necessary, use additional vapor barrier.In addition to the above, there are various methods for moisture-proof and moisture-monitoring by design or by the method ByggaF suited for the entire construction process various events..

Hänsyn till mark och vatten vid slutavverkning : en fältstudie på känsliga marker

The purpose of this study is to investigate if there is enough consideration taken to sensitive forest areas close to water or wetlands during clear cutting assignments, and to estimate the extent of damage made by forestry machines used at that time. A field and literature study is used to show how to improve and prevent the damage made in the wake of the machines. This study is made for Sydved, and shall culminate in a policy to prevent ground damage during their clear cutting assignments. The areas which were part of the field studies were clearcuttings on fine grained soil close to water and wetlands. The purpose was to find out if the water had been affected, what had been done to prevent ground damages and what more could have been done. The results of the field studies show that more work needs to be done to reach up to expectations. More information about the assignment area, better planning of sensitive regions, and strengthening of the main haul roads with brush are some of the improvements that can be done. There is also a need for more exact guidelines, follow-ups and education for everyone involved to have the same goals and understanding to prevent ground damage..

Effektiv lagerstyrning genom tillförlitlig prognostisering : Effective inventory control through reliable forecasting

This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab.The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics.The background of the problem with moisture is that today?s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate.

Tätning eller ventilering mot fukt på kalla vindsutrymmen

This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab.The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics.The background of the problem with moisture is that today?s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate.

Utfackningsväggar ur lufttäthets- och fuktsäkerhetsperspektiv : En jämförelse mellan platsbyggda och prefabriceradeutfackningsväggar

The swedish national board of housing, Building and Planning,recommends that all stakeholders in the construction industryperform a moisture control design to make sure that the buildingachieves good moisture resistance. Since June 1, 2006 there are nospecific requirements or quantitative values for air leakage.Although the swedish national board of housing does presentrequirement that the building envelope must be sealed so that theclient?s requirements for specific energy consumption and installedelectric power for heating purposes are met. Despite this, studiesfrom SP shows that few buildings meet the client?s requirements inspecific energy, which increases the risk of occurrence ofcondensation-related moisture damage.This study aims to evaluate curtain walls connections from airsecurity and moisture safety.

Fuktskydd och planering i byggprojekt ? Erfarenheter från Eolshäll

When the Eolshällproject was completed for the first time, a great deal of moisturedamage was discovered. Therefore the structure completion was removed andreinstalled. The project was originally planned to cost a total of 126 million SEK, but thefinal costs landed on 271 million SEK. What caused this failure? Were the designs poor,was the technology used too advanced, or was the project not managed properly?Based on the Eolshällproject, theses will be presented about what may have caused themoisture damage.

Stöldskydd

To save energy it?s popular to build houses with low energy loss. In these houses the walls are keeping a lower temperature in the external side which leads to a higher relative humidity. In addition more material, such as wood studs, are used which means that there is more moisture to dry. More moisture in combination with higher relative humidity may pose a higher risk of microbial growth.

Fuktskador i våtrum relaterat till tätskikt bakom keramiska plattor

Tile covered bathrooms require a wellexecuted waterproofing in order toprotect the underlying construction frommoisture. Länsforsakringar Uppsala paysannually out millions in insurance fordamages related to poor waterproofedbathrooms. In recent years, SP (SwedishNational Testing and Research Institute)investigated and researchedwaterproofing products, resulting ingreater shortcomings of product defectsthan expected.This report raises the problemsconcerning waterproofing and discusseswhy they occur. By studying productinstructions and insurance cases anddamage reports provided byLänsforsakringar, the most commonproblems concerning bathroomwaterproofing where concluded. Animportant part of the report was tofind out the actual cause to whywaterproofing damages occur.The results of the survey indicate thata common cause of water damage usuallyis related to poor productinstallations.

EAS-tagg med fuktsensor : Design och utvärdering av EAS-alarmteknologi för fuktdetektering

Electronic article surveillance (EAS) is widely used in shops and libraries together with an RF-tag attached to the goods or books in order to prevent shoplifting. By implementing the addition of a moisture sensor to the RF-tag, other functions become possible, including the ability to use as an alarm with regards to frozen goods, which have been shipped but which have melted and have, subsequently, refrozen. In- relation to care for the elderly, one time-consuming step involves checking whether there is the necessity for a change of diaper and this can, instead, be based on an RF-tag with an EAS-system alarm. A preliminary investigation was made using the moisture sensors, which involved how the resistance changes when liquid and/or heat is applied. A simulation of the LCCR circuit (RF-tag with the sensor) was conducted in order to determine how the resonance frequency changes for different resistances levels.

Elevers syn på teknikämnet : En jämförelse mellan svenska och sydafrikanska elevers tankar om teknik och teknikämnet

Tile covered bathrooms require a wellexecuted waterproofing in order toprotect the underlying construction frommoisture. Länsforsakringar Uppsala paysannually out millions in insurance fordamages related to poor waterproofedbathrooms. In recent years, SP (SwedishNational Testing and Research Institute)investigated and researchedwaterproofing products, resulting ingreater shortcomings of product defectsthan expected.This report raises the problemsconcerning waterproofing and discusseswhy they occur. By studying productinstructions and insurance cases anddamage reports provided byLänsforsakringar, the most commonproblems concerning bathroomwaterproofing where concluded. Animportant part of the report was tofind out the actual cause to whywaterproofing damages occur.The results of the survey indicate thata common cause of water damage usuallyis related to poor productinstallations.

LÖNSAMHETSKALKYL AV FUKTSÄKERHETSANSVARIG VID RENOVERING : En fallstudie av ett projekt där ByggaF-metoden har använts

The so called ?ByggaF-method? is a relatively new Swedish method to stop moisture from being built into a building. The method should prevent damages on buildings as a result of mould growth and moisture. The purpose of the method is to include moisture control in the entire constructionprocess, from the projecting phase and all the way to the management phase. Up until now, there is no proof if the method is profitable or not and no studies have been made on the topic.